| | The Oracle Infrared Forced Air Vaporizer Standard System with Inflation Kit | |       | | | Introduction to the Oracle Vaporizer Standard System:
Potent, active, and flavourful ingredients extracted via vaporization are healthier and easier on the body than smoke created via combustion. Harsh chemicals and carcinogens are not released by the plant material when precise temperatures are applied and maintained.
The Oracle Vaporizer’s ultra-modern patent pending technology utilizes an infrared heating system unparalleled the world over. Resulting in ‘On Demand‘ vapor production, The Oracle guarantees no long warm-up times, no need for excessive parts or overly complicated devices, and no toxic smoke.
By tuning The Oracle’s dial to a specific temperature, harvesting the vapor material is made incredibly
simple and accurate. In addition to the classic hose and/or bag operation, The Oracle is also excellent for Aromatherapy, Cooking, and Mixology applications.
Features:
• Infrared. Our Patent pending heat chamber design is the only one of it’s kind. Ever.
• On-Demand. The fastest and most effective in the industry, our vaporizer system is ready when you are. Just one button away.
• Aerogel. The world’s best insulator, often found in NASA laboratories, is the major component of our thermal protection.
• Food Grade Materials. The Oracle Infrared Vaporizer’s uses a food grade resevoir and silicone tubing, ready for deployment in the busiest of kitchen or commercial application,
right out of the box.
• Clean Air. Our multi-layered filtration system ensures created vapors are as true to their natural taste as possible.
• High Efficiency. Accuracy at High Temperatures combined with fast bag inflation times make sure you get the absolute best vapor extraction possible.
• RoHS Compliant. The Oracle Infrared Vaporizer uses no lead or mercury in it’s construction.
Quick Vape Guide:
1) Vaporizers Ready...
Place your Oracle Vaporizer on a dry, level surface, plug in the A/C cable, and make sure the chamber opening is clear of obstructions.
2) Take Your Mark...
Grind your dry biomass into small pieces and gently pour it into the bowl. For optimal infrared coverage, do not pack the biomass densely, or above the frosted glass.
3) Get Set...
Carefully slide the bowl into the chamber. Choose one of the Oracle Glass Adapters depending on your intended use. The “Straight Stack” offers a direct bag connection, while the “Hookah Stack” also includes hose functionality.
*Make sure the screen is in place on the bottom of the stack adapter before inserting the bag*
4) Go !
Tune the dial to your desired temperature, and press the button. You will immediately see the glow of infrared and hear the bag filling. Within 10 seconds there is potent vapor production. A 24” bag fills in about 2 minutes.
Temperature Reference:
The Oracle Infrared Vaporizer provides extremely accurate (+/-3?C) temperature control between 100?F and 450?F via the dial on the front of the unit.
Turning the dial clockwise will raise the ambient temperature inside the chamber by applying more short-wave infrared energy.
Turning the dial counter-clockwise will decrease the temperature while still utilizing forced-air to produce potent vapor.
To find the “Sweet Spot” temperature for your particular biomass, simply tune the dial until the resulting vapor looks and tastes right.
For more precise temperature control, please
refer to the manual.
Click here for the Oracle Vaporizer Standard Instruction Manual
Limited Warranty:
The manufacturer warrants this device will be free from defects in material, operation and workmanship
under normal use conditions for a period of one year from the date of purchase. This warranty only
applies to the original customer (purchaser) and is void if the unit is resold. This warranty does not
cover damage due to abuse, neglect, normal wear and tear or any other use not mentioned in the
manual. Upon receipt of the unit, the customer shall carefully inspect all parts for visible defects and
report any issues to the manufacturer immediately. Any attempt to take the Oracle apart will void the
warranty.
|
The Oracle Vaporizer Standard System comes with the following:
1 x Oracle Infrared Vaporizer
1 x 3’ Modular A/C Cable
1 x Air Filter
1 x Dry Biomass Bowl
1 x Straight Stack Adapter
1 x Hookah Stack Adapter
1 x Vapor Bag Adapter
1 x 36” Silicone Hose
1 x Hose Clamp
3 x 24” Vapor Bags
6 x 3” Bag Ties
1 x Rubber O Ring
2 x Stainless Adapter Screens
2 x Stainless Bowl Screens
The Oracle houses a 400W infrared
emitter designed for the safe production
of temperatures suitable for vaporization.
WARNING: Never look into the infrared
chamber while the unit is on.
Technical Specifications:
Voltage: 120V
Temperature Range: 100 - 450 ?F
Temperature Acceleration: 50 ?F/second
Warm up time (75 - 375 ?F): 8 Seconds
Heating Method: Forced Air Infrared
Heating Element: 400W Short Wave Emitter
Inhalation Method(s): Hose & Bag
Design: Stainless Steel
Temperature Accuracy: +/- 3 ?C
Power Connection: Modular
Pump Flow Rate: <13lpm
Safety:
• This device should not be used by underage or unqualified persons.
• Keep any liquids away from the chamber opening.
• Never put containers filled with liquids directly on top of the vaporizer.
• For indoor use only.
• Always operate on a flat and stable surface.
• Vaporizer should not be used in damp or wet conditions.
• Vaporizer should be cleaned with a dry cloth. If using a damp cloth to clean the exterior, ensure the power cord is removed from the unit first.
• Do not operate the unit without a bowl in the chamber.
• Do not use in an environment where a risk of explosion or ignition is present.
• Do not leave the unit unattended while it is running.
• Do not start or leave the unit running on red temperature settings longer than 30
seconds to avoid combustion of your biomass.
• Ensure the stated voltage on the warning sticker corresponds with your areas electrical outlet specifications.
• If there are any problems during operation, immediately pull out the plug.
• Ensure the cord is kept unwound during operation and that it does not rub against any sharp surfaces. If you notice a tear in the jacketing replace the power
cord prior to use.
• Never open the case at any time due to the danger of exposed live contacts.
• Do not touch the chamber glass during or immediately after operation.
• Do not put fingers or any part of the body inside the chamber.
• Do not touch the bowl when it is hot aside from the black insulation strip.
• Ensure any glass adapter pieces are sufficiently cooled prior to removing them.
• Ensure the bag joint is sufficiently cooled prior to inhalation.
• Do not stare directly into the infrared chamber when it is empty and turned on.
• Do not put any body parts or objects near or above the exhaust vent while in use.
• Do not use the device with any accessories not provided by the manufacturer as they may create a potential hazard.
• The packaging materials including plastic and Styrofoam should be kept out of reach of children at all times as they pose a choking hazard.
• Repairs on the unit should only done by certified technicians at manufacturer's office as per the warranty instructions.
|
|  |
|
| | you may also like |  | |
|